GAOFEN-3 products are processed to a Level-1D with the two steps below:

\[ DN_{true} = DN_{image} \times {QualifyValue \over 32767} \]

and

\[ \sigma_0 = 10 \times log_{10}(DN_{true}^2) - CalibrationConst \]

with \( QualifyValue \) and \( CalibrationConst \) values found in the product metadata

Input

The input is an ingested GAOFEN-3, see details here.

Output

The output is a STAC item geojson ... including the assets ...

References

  • Chang, Y.; Li, P.; Yang, J.; Zhao, J.; Zhao, L.; Shi, L. (2018), “Polarimetric Calibration and Quality Assessment of the GF-3 Satellite Images”, Sensors 2018, 18, 403. DOI: https://doi.org/10.3390/s18020403