GAOFEN-3 products are processed to a Level-1D with the two steps below:
\[
DN_{true} = DN_{image} \times {QualifyValue \over 32767}
\]
and
\[
\sigma_0 = 10 \times log_{10}(DN_{true}^2) - CalibrationConst
\]
with \( QualifyValue \) and \( CalibrationConst \) values found in the product metadata
Input
The input is an ingested GAOFEN-3, see details here.
Output
The output is a STAC item geojson ... including the assets ...
References
-
Chang, Y.; Li, P.; Yang, J.; Zhao, J.; Zhao, L.; Shi, L. (2018), “Polarimetric Calibration and Quality Assessment of the GF-3 Satellite Images”, Sensors 2018, 18, 403. DOI: https://doi.org/10.3390/s18020403
-
i, X.-M.; Zhang, T.; Huang, B.; Jia, T. (2018), “Capabilities of Chinese Gaofen-3 Synthetic Aperture Radar in Selected Topics for Coastal and Ocean Observations”, Remote Sens. 2018, 10, 1929. DOI: https://doi.org/10.3390/rs10121929